Fuses

Customers who viewed this product also viewed

POWR-GARD JLS Fast-Acting 600 VAC 125A Class J Fuse
POWR-GARD JLS Fast-Acting 600 VAC 125A Class J Fuse

Amp-trap 2000 SmartSpot AJT Time Delay 600V 100A J Fuse
Amp-trap 2000 SmartSpot AJT Time Delay 600V 100A J Fuse

POWR-GARD JLS Fast-Acting 600 VAC 70A Class J Fuse
POWR-GARD JLS Fast-Acting 600 VAC 70A Class J Fuse

Amp-trap 2000 SmartSpot AJT Time Delay 600V 250A J Fuse
Amp-trap 2000 SmartSpot AJT Time Delay 600V 250A J Fuse

Amp-trap 2000 SmartSpot AJT Time Delay 600V 80A J Fuse
Amp-trap 2000 SmartSpot AJT Time Delay 600V 80A J Fuse

Amp-trap 2000 SmartSpot AJT 30A Time Delay Fuse, J Fuse
Amp-trap 2000 SmartSpot AJT 30A Time Delay Fuse, J Fuse

Amp-trap 2000 SmartSpot AJT Time Delay 600V 60A J Fuse
Amp-trap 2000 SmartSpot AJT Time Delay 600V 60A J Fuse

Amp-trap 2000 SmartSpot AJT Time Delay 600V 500A J Fuse
Amp-trap 2000 SmartSpot AJT Time Delay 600V 500A J Fuse

Ferraz Shawmut Amp-trap 2000 SmartSpot AJT Time Delay 600V 50A Class J Fuse

Amp-trap 2000 SmartSpot AJT Time Delay 600V 50A J Fuse

*Image Accuracy Not Guaranteed

Product Data Sheet

Printable Page



Product Name: Amp-trap 2000 SmartSpot AJT Time Delay 600V 50A J Fuse

Product #: AJT50

Manufacturer: Ferraz Shawmut

Unit of Measure: Each (1)

Our Price/Unit: $20.22

Average Wholesale Price/Unit: $22.88

You Save: $2.66 (13.16%)/Unit

Quantity of Units/Case: 10

Minimum Quantity of Cases to Order: 1

Your Price per Case: $202.20

Product Info

MAXIMUM CIRCUIT PROTECTION, MINIMAL SIZE Amp-trap 2000 SmartSpot AJT fuses now provide a visual open fuse indicator. With advanced material technology added to the existing product line the AJT fuse provides IEC Type 2 (No Damage) protection to main, feeder, and branch circuits, for all types of loads - yet, they require only half the mounting space needed for 600VAC Class RK fuses. AJTs time delay characteristics for handling harmless in-rush currents, its current limiting ability (the most current limiting UL fuse class!), and wide range of ratings (from 1 to 600 Amperes) - give excellent protection for all your applications. A mechanical Indicator/Microswitch Mount (EI) is available on blade-type (70 to 600A) fuses for visual or remote indication of open fuse condition.

Specifications

Class: J

Cross Reference: LPJ, JTD, JDL, JHC

Fuse Amp Rating: 50

Industry Standards: UL

Length: 2-3/8

Voltage: 600

Width: 1-1/16

Review

Be the first to review our Ferraz Shawmut Amp-trap 2000 SmartSpot AJT Time Delay 600V 50A J Fuse